Description
The intelligent public access defibrillator (iPad CU-SP1) is a device that is designed to make it easier for first responders to use an automated external defibrillator (AED). The iPAD CU-SP1 listens to the ambient noise and automatically adjusts the volume of its prompts to make them clear and easily heard over the background noise. When the correct volume has been reached, the iPAD CU-SP1 keeps the prompts at this level. The iPAD CU-SP1 also has smart pads that are pre-connected and stored in a clear storage compartment on the underside of the unit. This ensures that the unit is always ready to be used. The iPAD CU-SP1 also has CPR detection and encourages the first responder if CPR is not being performed. The iPAD CU-SP1 also has easy communication with the CU-EX1 software, which allows first responders to get information from the unit after an event.
AUTO VOLUME ADJUST
Public places can often be noisy. Crowded stations, airports with constant announcements and streets filled with cars and people often make it difficult to hear whats going on around you. Trying to use an AED in noisy places can be difficult if the first responder cant clearly hear the voice prompts and instructions from the AED. The iPAD CU-SP1 listens to the ambient noise, and automatically adjusts the volume of its prompts to make them clear and easily heard over the background noise. When the correct volume has been reached the iPAD CU-SP1 keeps the prompts at this level
SMART PADS - SMART STORAGE!
The pre-connected Smartelectrode pads are stored in a clear storage compartment on the underside of the unit. This ensures that the iPAD SP1 is always ready to be used in the shortest amount of time possible. The unique technology built in to the iPAD CU-SP1 and the Smartelectrode pads allows the unit to detect, when connected, if a set of pads has already been used. If they have, the user is advised of this. In addition, the visual indicator on the front of the iPAD CU-SP1 indicates if the connected pads are within their life expectancy. The indicator will change when the pads have only 3 months life left before their expiry date-giving you plenty of time to arrange for replacements. The indicator will change again when the expiry date is reached. Checking the life of your pads is as quick and simple as looking at the LCD display.
CPR DETECTION
CPR is vital to ensure that the casualty has the best chances of survival. The iPAD CU-SP1 detects if CPR is being performed when appropriate prompts and encourages the first responder. If CPR is not being performed, the iPAD CU-SP1 prompts the first responder to perform CPR. If CPR is already being performed, the iPAD CU-SP1 encourages the first responder by prompting them to continue CPR.guide the users.
EASY COMMUNICATION WITH CU-EX1 SOFTWARE
Getting information from the iPAD CU-SP1 after an event is now easier than ever! Installing CU-EX1 software onto a computer allows you to see and analyse the usage history of the unit. Information such as time of power on, the casualtys heart rhythm and shocks delivered are all presented in an easy to understand fashion. The iPAD CU-SP1 can store up to 5 events with up to 3 hours of ECG analysis on an SD memory card. The data can be transferred by either simply removing the SD card, or by using the inbuilt infra-red (IrDA) port. Having the data on an SD Memory card allows the card to be removed for analysis whilst another card is inserted, making the unit ready to use again whilst retaining the original information.
TECHNICAL SPECIFICATIONS
1) DEFIBRILLATOR
Standard Packgage Defibrillator, Pads, Battery, Manual
Output Energy Adult-150Joules /
Pediatric-50Joules (Common usage)
Charging time
1) Charging time : Less than 8 seconds
2) Charging time after CPR finished : At least 8 seconds
2) USER INTERFACE
User support Detailed voice prompts and flashing
Indicators
CPR guidance Voice prompts for how to perform CPR for
Adult and child patient
Controls On/Off button, I button, Shock button
Indicator LCD display
(Device status, Battery status, Pads status)
Sensing Pads expiring date, Pads connection status
CPR Monitoring
Automatic Volume adjusting
3) ENVIRONMENT
Sealing Waterjet proof IPX5 per IEC60529 (IP55)
Dust protected IP5X per IEC60529
Temperature Operation/standby (0 - 40 )
Vibration Meets MILSTD 810F
4) DATA RECORDING AND TRANSMISSION
IrDA port wireless transmission of event data to PC, SD Card
Internal Memory (Nand-flash) ECG, Event
Storage capacity Multi recording 5 events / Max 3 hours
Data review PC Program CU-EX1
5) PATIENT ANALYSIS SYSTEM
Patient Analysis Shockable Rhythms - Ventricular Fibrillation,
Ventricular Tachycardia
Sensitivity/Specificity Meets AAMI DF80 Guideline
6) BATTERY
Standard
+ Type : DC 12 Volt 2.8 Ah, Lithium manganese dioxide
+ Capacity : Minimum 100shocks (150J )
High Capacity
+ Type : DC 12Volt 4.2Ah, Lithium manganese dioxide
+ Capacity : Minimum 200shocks (150J )
Lifespan 5 year