Black Friday Early Deals Now Live!
VIEW DEALS

Syringe Pump Driver KL605T



Syringe Pump Driver KL605T
The Syringe Pump Driver KL605T is a medical device that is used to infuse medications into the body. It has a flow rate of 0.1-1200 ml/h, a bolus rate of 0.1-100 ml/h, and a body weight limit of 50 kg. It has a pressure sensor error and a syringe installation error. The device also has an anti-bolus function, a mute button, and a purge function. The device has a history log that records 50,000 eve... more details
Key Features:
  • Flow rate of 0.1-1200 ml/h
  • Bolus rate of 0.1-100 ml/h
  • Body weight limit of 50 kg


R15 319.90 from Cleansafe Labs

price history Price history

   BP = Best Price   HP = Highest Price

Current Price: R15 319.90

loading...
Features
Brand Unbranded
Manufacturer Unbranded
Model Number SYRP605T
Description
The Syringe Pump Driver KL605T is a medical device that is used to infuse medications into the body. It has a flow rate of 0.1-1200 ml/h, a bolus rate of 0.1-100 ml/h, and a body weight limit of 50 kg. It has a pressure sensor error and a syringe installation error. The device also has an anti-bolus function, a mute button, and a purge function. The device has a history log that records 50,000 events.

Syringe Pump KL605T
Specifications
Model KL-605T
Syringe Sizes 5,10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
VTBI 1-1000 ml in 0.1 , 1 , 10 ml increments
Flow Rate
Syringe 5ml : 0.1-100 ml/h (in 0.01 , 0.1 , 1 , 10ml/h increments)
Syringe 10 ml: 0.1-300 ml/h
Syringe 20 ml: 0.1-600 ml/h
Syringe 30 ml: 0.1-800 ml/h
Syringe 50/60 ml: 0.1-1200 ml/h
Bolus Rate Syringe :
5ml: 0.1-100ml/h (in 0.01 , 0.1 , 1 , 10ml/h increments)
10 ml: 300 ml/h Syringe
20 ml: 600 ml/h Syringe
30 ml: 800 ml/h Syringe
50/60 ml: 1200 ml/h
Anti-Bolus Automatic
Accuracy 2% (mechanical accuracy 1%)
Infusion Mode
Flow rate: ml/min, ml/h
Time-based
Body weight
KVO Rate 0.1-1 ml/h (in 0.01 ml/h increments)
Alarms Occlusion, near empty, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, reminder alarm,
pressure sensor error, syringe installation error, syringe drop off
Additional Features Real-time infused volume, automatic power switching,
automatic syringe identification, mute button, purge, bolus, anti-bolus,
system memory
Drug Library Available
History log :50 000 events
Occlusion Sensitivity High, medium, low
Power Supply, AC 110/230 V (optional), 50/60 Hz, 20 VA
Battery 14.8 V, rechargeable
Battery Life8 hours at 5 ml/h
Working Temperature 5-40
Relative Humidity 20-90%
Atmospheric Pressure 700-1060 hpa
Size 245*120*115 mm
Weight 2.5 kg
Safety Classification Class II, type BF
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.