Simulator MS100 SPO2



The MS100 simulator is a device that allows for the testing of medical devices. It has a separated connection between the probe and the host, which makes the operation and test more convenient. It also has a 262K color and 320*240 TFT display, adjustable brightness level, film key-press, and power with a chargeable lithium battery. The key volume, can open or close, and main functions are oxygen s... more details
Key Features:
  • Separate connection between probe and host makes testing more convenient
  • 262K color and 320*240 TFT display
  • Adjustable brightness level


From
R35 968.76 at 2 Shops

price history Price history

   BP = Best Price   HP = Highest Price

Current Price: R35 968.76

loading...
Features
Brand Unbranded
Manufacturer Unbranded
Model Number SIM100S
Description
The MS100 simulator is a device that allows for the testing of medical devices. It has a separated connection between the probe and the host, which makes the operation and test more convenient. It also has a 262K color and 320*240 TFT display, adjustable brightness level, film key-press, and power with a chargeable lithium battery. The key volume, can open or close, and main functions are oxygen saturation simulation, pulse rate simulation, patient state simulation, and test performance under different interference sources. The main parameters are SpO2 measuring range: 35%~100%, resolution: 1% error, pulse rate measuring range: 25bpm~250bpm, resolution: 5bpm error, amplitude measuring range: 0.000%~20.000%, resolution: 1% for 1.000%~20.000%; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%. The patient state has 24 conditions preset and 8 conditions as default after start. The number of condition can be adjusted by Motion level setup. The voltage is DC 3.6V~4.2V and the power supply is a voltage 3.7 rechargeable lithium battery *

Simulator MS100 SPO2
Features
Separated connection between simulator probe and host, operation and test are more convenient.
262K color and 320*240 TFT, adjustable brightness level.
Film key-press, makes the operation more comfortable.
Power with chargeable lithium battery, can display the charge information of battery.
Key volume, can openorclose.
Main Functions
Oxygen saturation simulation;
Pulse rate simulation;
Patient state simulation preset;
Can test the reaction time of device;
Can simulate the SpO2 and pulse rate under different amplitude;
Can test the performance of device under different interference source;
Canselectdifferent R-curve.
Main Parameters
SpO2
Measuring range: 35%~100%
Resolution:1%
Error: When SpO2 is 75%~100%, the error is the larger between 2% and P(P denotes the precision of the tested oximeter); when SpO2 is 74%~50%, the error is the larger between 2% and P; no define when SpO2 is less than 50%.
Pulse rate
Measuring range:25bpm~250bpm
Resolution:5bpm
Error:1%1bpm
Amplitude
Measuring range:0.000%~20.000%
Resolution:1% for 1.000%~20.000%; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%.
Patient state
24 conditions presetting and 8 conditions as default after start. The number of condition can be adjusted by Motion level setup.
Voltage
DC 3.6V~4.2V
Power Supply
Voltage 3.7 rechargeable lithium battery * 1
Battery working life
Charge and discharge no less than 500 times.
Accessaries
A MS100 user manual
A 5.0V adaptor