Description
This is a 3000VA AVR Line Interactive UPS. It features a smart microprocessor control design, AVR Boost and Buck, Smart RS232/USB Interface, and Cold Start Function. It also has a cost-effective solution to your mission-critical PC and valuable peripherals. It features AVR Boost and Buck, Cold Start Function, Smart RS232/USB Interface for Power Management, Built-in Self-diagnostic Function, Modem/LAN Internet Protection, and Compatible with Generator Set. It also has Average Power 3000VA, RMS Power 1800W, and Input Voltage: 230V AC, 162V AC - 290V AC. It also has Output Voltage: 230V AC, +10% to -10%, 49Hz to 51Hz (50Hz), 2ms to 6ms. It also has Battery Type: 12V 9AH, Battery Quantity: 4, Battery String Voltage: 48V, Storage Capacity (Watt Hours): 432Wh, Battery Recharge Time: Six to Eight Hours, and Standard Protection: Surge/Lightning Protection, AVR Buck and Boost Control, Cold Start Function, and Double Boost to correct low input voltage and single buck to protect high input voltage conditions.
3000VA AVR Line Interactive UPS. Featuring a smart microprocessor control design, AVR Boost and Buck, Smart RS232/USB Interface, and Cold Start Function. A cost-effective solution to your mission-critical PC and valuable peripherals.
Features:
AVR Boost and Buck
Cold Start Function
Smart RS232/USB Interface for Power Management
Built-in Self-diagnostic Function
Modem/LAN Internet Protection
Compatible with Generator Set
LCD Display
Fastest Charging Capacity
Auto Charging in Off Mode
SPECIFICATIONS
Average Power 3000VA
RMS Power 1800W
INPUT
Rated Input Voltage:
Accepted Input Voltage Range:
Input Frequency:
230V AC
162V AC - 290V AC
50Hz
OUTPUT
Rated Output Voltage:
Voltage Regulation (On Battery):
Frequency Range (On Battery):
Mains to Battery Transfer Time:
Output Waveform (On Battery):
230V AC
+10% to -10%
49Hz to 51Hz (50Hz)
2ms to 6ms
Simulated Sinewave
BATTERY
Battery Type:
Battery Quantity:
Battery String Voltage:
Storage Capacity (Watt Hours):
Battery Recharge Time:
Standard Protection:
Surge/Lightning Protection:
AVR Buck and Boost Control:
Cold Start Function:
12V 9AH
4
48V
432Wh
Six to Eight Hours
Overload, Battery Discharge, and Battery overcharge protection
>400V for 2-seconds (Live to Neutral, Live to Earth, and Neutral to Earth)
Double Boost to correct low input voltage and single buck to protect high input voltage conditions
Yes - Unit will power up without mains voltage on the input
BATTERY
Battery Type:
Numbers:
Typical Recharge Time:
Charging Current (max.):
Charging Voltage:
12 V / 9 Ah
4
4 hours recover to 90% capacity
1 A
54.7 VDC 1%
LAN / Telephone Protection Yes - Two RJ45 Ports provide surge and spike protection for LAN cable
Generator Compatibility