MASSIVE SAVINGS JUST FOR YOU!
VIEW DEALS

Zero Appliances 12GEYSERZERO Gas Water Heater With Flu Pipe 12L



The 12GEYSERZERO Gas Water Heater with Flu Pipe is a high-efficiency gas water heater that has a capacity of up to 20 liters per minute. It has a low water pressure start (0.1 bar / 0.01mPA) but needs 1.5 bar for maximum output. The means of exhaust is by flue pipe, and it has a fully automatic battery type ignition system. It also has automatic flame failure protection, over temperature and over ... more details
Key Features:
  • 20 liter/minute water flow rate
  • Low water pressure start (0.1 bar / 0.01mPA)
  • 1.5 bar water pressure requirement for maximum output


From
R3 999.00 at 2 Shops

price history Price history

   BP = Best Price   HP = Highest Price

Current Price: R3 999.00

loading...
Features
Brand Unbranded
Manufacturer Zero Appliances
Model Number 6007282000616
Description
The 12GEYSERZERO Gas Water Heater with Flu Pipe is a high-efficiency gas water heater that has a capacity of up to 20 liters per minute. It has a low water pressure start (0.1 bar / 0.01mPA) but needs 1.5 bar for maximum output. The means of exhaust is by flue pipe, and it has a fully automatic battery type ignition system. It also has automatic flame failure protection, over temperature and over pressure protection. The 12GEYSERZERO Gas Water Heater with Flu Pipe has a 20 minutes built-in time device and indicator, and it has a double pulse ignition system with high ignition efficiency.

Capacity Consumption Dimensions Weight

8 l per minute 1.5 kg/hr (H) 664mm x (W) 340mm x (D) 224mm 8kg

12 l per minute 2.25 kg/hr (H) 710mm x (W) 405mm x (D) 224mm 10kg

16 l per minute 3 kg/hr (H) 776mm x (W) 446mm x (D) 224mm 12kg

20 l per minute 3.75 kg/hr (H) 778mm x (W) 500mm x (D) 228mm 15kg



Characteristics:

1. Gas Type: LPG

2. Gas Pressure: 2800 Pa/2000 Pa/2.8 kPa

3. Low Water Pressure Start (0.1 Bar / 0.01mPA) But Needs 1.5 Bar For Max Output

4. Means of Exhaust: By Flue Pipe

5. Ignition Method: Fully Automatic Battery Type

6. Automatic Flame Failure Protection, Over Temperature & Over Pressure Protection

7. 20 Minutes Built-in Time Device and Indicator

8. Double Pulse Ignition System With High Ignition Efficiency



**N.B Difficulty may be experienced when using reduced output shower heads i.e. often restricted to 10L per minute.



**Includes Flu Pipe.



**All other extension pipes and fittings will be provided by your qualified gas installer in accordance to your needs**



1 Year Fault Guarantee



Warranty and void without a Certificate of Compliance
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.