MASSIVE SAVINGS JUST FOR YOU!
VIEW DEALS

Bowie Dick Test Packs 1'S



The Bowie-Dick test is used to evaluate the performance of the air removal system of a pre-vacuum assisted sterilizer. The test consists of a folded 100% cotton surgical towel that is clean and preconditioned. The pack should be placed horizontally in the front, bottom section of the sterilizer rack, near the door and over the drain, in an otherwise empty chamber and run at 134C for 3.5 minutes. I... more details
Key Features:
  • Used to evaluate the performance of sterilization systems
  • Consists of a folded 100% cotton surgical towel
  • Clean and preconditioned


R52.00 from Oxyaider Pty Ltd

price history Price history

   BP = Best Price   HP = Highest Price

Current Price: R52.00

loading...
Features
Brand Unbranded
Manufacturer Unbranded
Description
The Bowie-Dick test is used to evaluate the performance of the air removal system of a pre-vacuum assisted sterilizer. The test consists of a folded 100% cotton surgical towel that is clean and preconditioned. The pack should be placed horizontally in the front, bottom section of the sterilizer rack, near the door and over the drain, in an otherwise empty chamber and run at 134C for 3.5 minutes. If the sterilizer fails the Bowie-Dick test, do not use the sterilizer until it is inspected by the sterilizer maintenance personnel and passes the Bowie-Dick test.

Bowie Dick Test Packs
Bowie Dick Test Pack for Sterilization
Bowie & Dick Test Packs are pre-assembled, single use test packs designed to evaluate the performance of the air removal system of pre-vacuum assisted sterilizers.
Color changed: from yellow to black
Operation Condition: 1323-5min
A Bowie-Dick test is used in pre-vacuum type (or dynamic air removal) sterilizers. They are used to detect air leaks and inadequate air removal and consist of folded 100% cotton surgical towels that are clean and preconditioned. A commercially available Bowie-Dick-type test sheet should be placed in the center of the pack. The test pack should be placed horizontally in the front, bottom section of the sterilizer rack, near the door and over the drain, in an otherwise empty chamber and run at 134C for 3.5 minutes. The test is used each day the vacuum-type steam sterilizer is used, before the first processed load.Air that is not removed from the chamber will interfere with steam contact.Smaller, commercially available disposable test packs (or process challenge devices) have been devised to replace the stack of folded surgical towels for testing the efficacy of the vacuum system in a pre vacuum sterilizer. They should be representative of the load and simulate the greatest challenge to the load.Sterilizer vacuum performance is acceptable the sheet inside the test pack shows a uniform color change.Entrapped air will cause a spot to appear on the test sheet, due to the inability of the steam to reach the chemical indicator. If the sterilizer fails the Bowie-Dick test, do not use the sterilizer until it is inspected by the sterilizer maintenance personnel and passes the Bowie-Dick test.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.