Description
The syringe pump is a medical device that is used to infuse medications into a patient. It has a real-time infusion volume feature, an automatic power switching feature, and an automatic syringe identification feature. It also has a mute button, a purge function, a bolus function, an anti-bolus function, a system memory, a history log, and a key locker.
Syringe Pump - KL-602
Additional Features
Real-time infused volume, automatic power switching, automatic syringe identification, mute button, purge, bolus, anti-bolus, system memory, history log, key locker, separate channel alarm, power saving mode
Product Description
Medical Programmable Automatic Syringe Pump with Ce Approved
Note: Portable Electronic injection single channel ambulance syringe pump is compatible with syringe of any standard.
Features(optional):
1) Simple structure in linear type ,easy in installation and maintain.
2) Adopting advanced world famous brand components in pneumatic parts ,electric parts and operation parts.
3) High pressure double crank to control the die opening and closing.
4) Running in a high automatisation and intellectualisation pollution
5) Apply a linker to connect with the air conveyor ,which can directly inline with filling machine .
Features And Advantages:
High accuracy2%, high consistency.
Multiple work modes and multiple drug units
Anti-Bolus can release pressure automatically when occlusion alarms happens
Several occlusion pressure alarm can meet different pressure requirement for drugs, and improve the safety in the clinic use.
Key lock avoids mis operation and improve safety.
Specification
Model
KL-602
Syringe Size
10, 20, 30, 50/60 ml
Applicable Syringe
Compatible with syringe of any standard
VTBI
0.1-9999 ml
1000 ml in 0.1 ml increments
1000 ml in 1 ml increments
Flow Rate
Syringe 10 ml: 0.1-400 ml/h
Syringe 20 ml: 0.1-600 ml/h
Syringe 30 ml: 0.1-900 ml/h
Syringe 50/60 ml: 0.1-1300 ml/h
100 ml/h in 0.1 ml/h increments
100 ml/h in 1 ml/h increments
Bolus Rate
Syringe 10 ml: 400 ml/h
Syringe 20 ml: 600 ml/h
Syringe 30 ml: 900 ml/h
Syringe 50/60 ml: 1300 ml/h
Anti-Bolus
Automatic
Accuracy
2% (mechanical accuracy 1%)
Infusion Mode
Memory mode
Flow rate: ml/min, ml/h
Time-based
Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc.
KVO Rate
0.1-1 ml/h (in 0.1 ml/h increments)
Alarms
Occlusion, near empty, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, reminder alarm, pressure sensor error, syringe installation error, syringe drop off
Additional Features
Real-time infused volume, automatic power switching,
automatic syringe identification, mute key, purge, bolus, anti-bolus,
system memory
Drug Library
Available
Occlusion Sensitivity
High, medium, low
Power Supply, AC
110/230 V (optional), 50/60 Hz, 20 VA
Battery
9.61.6 V, rechargeable
Battery Life
7 hours at 5 ml/h
Working Temperature
5-40
Relative Humidity
20-90%
Atmospheric Pressure
860-1060 hpa
Size
314*167*140 mm
Weight
2.5 kg
Safety Classification
Class , type CF