MASSIVE SAVINGS JUST FOR YOU!
VIEW DEALS

Syringe Pump KL-605T



The Syringe Pump KL-605T is a time-based infusion pump that can infuse syringe sizes of 5 ml, 10 ml, 20 ml, 30 ml, 50 ml, and 60 ml. It has a flow rate of 0.1-1000 ml/h in 0.01, 0.1, 1, 10 ml/h increments, and a bolus rate of 0.1-100 ml/h. It also has an automatic syringe identification and a mute key. It has an accuracy of 2% (mechanical accuracy1%) and a infusion mode that is easy mode. It has a... more details
Key Features:
  • Time-based infusion pump
  • Can infuse syringe sizes of 5 ml, 10 ml, 20 ml, 30 ml, 50 ml, and 60 ml
  • Flow rate of 0.1-1000 ml/h in 0.01, 0.1, 1, 10 ml/h increments


R14 613.65 from Oxyaider Pty Ltd

price history Price history

   BP = Best Price   HP = Highest Price

Current Price: R14 613.65

loading...

tagged products icon   Similarly Tagged Products

Features
Brand Unbranded
Manufacturer Unbranded
Description
The Syringe Pump KL-605T is a time-based infusion pump that can infuse syringe sizes of 5 ml, 10 ml, 20 ml, 30 ml, 50 ml, and 60 ml. It has a flow rate of 0.1-1000 ml/h in 0.01, 0.1, 1, 10 ml/h increments, and a bolus rate of 0.1-100 ml/h. It also has an automatic syringe identification and a mute key. It has an accuracy of 2% (mechanical accuracy1%) and a infusion mode that is easy mode. It has a body weight limit of 50 kg and a plasma TCI of 1-1000 ml. It has an effect TCI of 0.1-1 ml/h. It has an alarms system that includes occlusion, near empty, end program, low battery, end battery, AC power off, motor malfunction, system malfunction, standby, and pressure sensor error. It also has a drug library and a system memory.

Syringe Pump KL-605T
Specifications
Model
KL-605T
Syringe Size
5, 10, 20, 30, 50/60 ml
Applicable Syringe
Compatible with syringe of any standard
VTBI
1-1000 ml (in 0.1, 1, 10 ml increments)
Flow Rate
Syringe 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)
Syringe 10 ml: 0.1-300 ml/h
Syringe 20 ml: 0.1-600 ml/h
Syringe 30 ml: 0.1-800 ml/h
Syringe 50/60 ml: 0.1-1200 ml/h
Bolus Rate
5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)
10 ml: 0.1-300 ml/h
20 ml: 0.1-600 ml/h
30 ml: 0.1-800 ml/h
50/60 ml: 0.1-1200 ml/h
Anti-Bolus
Automatic
Accuracy
2% (mechanical accuracy1%)
Infusion Mode
Easy mode
Flow rate
Time-based
Body weight
Plasma TCI
Effect TCI
KVO Rate
0.1-1 ml/h (in 0.01 ml/h increments)
Alarms
Occlusion, near empty, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby,
pressure sensor error, syringe installation error, syringe drop off
Additional Features
Real-time infused volume, automatic power switching,
automatic syringe identification, mute key, purge, bolus, anti-bolus,
system memory, history log
Drug Library
Available
Occlusion Sensitivity
High, medium, low
History Log
50000 events
Power Supply, AC
110-230 V, 50/60 Hz, 20 VA
Battery
14.8 V, rechargeable
Battery Life
8 hours at 5 ml/h
Working Temperature
5-40
Relative Humidity
20-90%
Atmospheric Pressure
700-1060 hpa
Size
245*120*115 mm
Weight
2.5 kg
Safety Classification
Class , type BF
Product Paramenters
Size
245*120*115 mm
Package Size
300*245*220 mm
Certification
CE
OEM
Accept
Wireless management
Optional
Flow rate
Wide range
KVO
Yes
Drug library
Yes
System
Open
Application
ICU, CCU, NICU, emergency, operation room, paediatrics, obstetrics, cardiology, oncology, hematology