MASSIVE SAVINGS JUST FOR YOU!
VIEW DEALS

Defi Xpress Defibrillator Monitor Biphasic With Aed & Built-in Printer



The Defi Xpress Defibrillator Monitor is a high-resolution display device that can be used to monitor a patient's heart rate, lead/pads, and oxygen saturation. The Defi Xpress also has a built-in printer that can print out ECG data. The Defi Xpress is available in three colors: grey, blue, and white. The Defi Xpress has a waveform: biphasic (BTE) charge time: less than 7 seconds with a new fully c... more details
Key Features:
  • High-resolution display device
  • Waveform: biphasic (BTE) charge time: less than 7 seconds with a new fully charged battery
  • Display that indicates both selected and delivered energy


R65 899.00 from Oxyaider Pty Ltd

price history Price history

   BP = Best Price   HP = Highest Price

Current Price: R65 899.00

loading...
Features
Brand Unbranded
Manufacturer Unbranded
Description
The Defi Xpress Defibrillator Monitor is a high-resolution display device that can be used to monitor a patient's heart rate, lead/pads, and oxygen saturation. The Defi Xpress also has a built-in printer that can print out ECG data. The Defi Xpress is available in three colors: grey, blue, and white. The Defi Xpress has a waveform: biphasic (BTE) charge time: less than 7 seconds with a new fully charged battery. The Defi Xpress also has a display that indicates both selected and delivered energy. The Defi Xpress has a charge prompt type: voice and visual prompts. The Defi Xpress has a patient connection: 3-lead ECG cable or 5-lead ECG cable paddles. The Defi Xpress has a lead selection: displayed on monitor paddles I II III AVR AVL AVF V. The Defi Xpress has an ECG size: 0.25 0.5 1 1.5 2 4 cm/mV display on monitor. The Defi Xpress has a heart rate: 20-300BPM. The Defi Xpress has a heart rate alarm: on/off displayed

Defi Xpress Defibrillator Monitor
With voice alarm which can meet your clinical needs from Basic Life Support (BLS)
to Advanced Cardiac Life Support (ACLS).
Available Color
Grey . Blue . White
Defibrillators benefit patients who experience a sudden case of heartbeat is arrhythmias. In these instances
Defibrillators are an important tool for anyone in the vicinity of a victim suffering from ventricular arrhythmia as well. arrhythmia renders the patient unconscious. the heart may beat too fast, too slow or an irregular mix of both. The anticipated outcome of sucharrhythmias is either cardiac arrest or a stroke.
Display
Screen Type: High-resolution display
Screen Size: 7 inches (17.7 cm) diagonally
Sweep Speed: 25mm/sec
Information: Heart Rate . Lead/Pads. Alarm . On/Off . SpO2 . AED
Functions and Prompts Alarm Selection and Limits Delivered Energy.
Defibrillator
Waveform: Biphasic (BTE)
Charge Time: Less than 7 seconds with a new fully charged battery.
Energy Display: Monitor display indicates both selected and delivered energy.
Charge Prompt Type: Voice and visual prompts.
Electrode Impedance Measurement Range: 0-250 ohms.
ECG Monitoring
Patient Connection: 3-lead ECG cable or 5-lead ECG cable paddles.
Lead Selection: Displayed on monitor paddles I II III AVR AVL AVF V.
ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV display on monitor.
Heart Rate: 20-300BPM.
Heart Rate Alarm: On/Off displayed on monitor user-selectable.
Smart Alarms: Beeper/voice prompts indicate shock able rhythm.
Battery
Type: Rechargeable Ni-MH battery 12V.
Operating time: For a new fully charged battery: 60 defibrillator discharges at maximum energy or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions.
SpO2 Module (Options):
Measurement Range: 30~100% 2% between 80%~90% others 5%
Alarm Range: User set high limit and low limit.
Alarm Accuracy: 10% within setting values.
Alarm time Accuracy: less than 12 sec.
1-Meditech Pulse Oximeter
2-Nellcor Pulse Oximeter
EtCO2 Module (Options):
CO2 Range0 to 13%098.8mmHg@BTPS
CO2 Accuracy5.0% CO2 (at BTPS) < 10% of reading
Breath Rate360 BPM
Measurement Accuracy1BPM
Pacemaker(Options):
Type: VVI
Pulse Type: rectangular,constant current
Pulse Amplitude: 0 to 180 mA 10% or 5 mA (whichever is greater).
Pacing Rate: Variable from 30 ppm to 180 ppm 1.5% (increments or decrements by a value of 2 ppm)
Multi-Function Electrode: (MFE) Pads: multipurpose defibrillation/pacing electrodes
Pause: Pacing pulse frequency reduced by a factor of 4 when activated
Refractory Period: NC(VVI demand do not have this specification)
Pulse Width: (20+ 1.5 ms)
Output Protection: Fully defibrillator protected and isolated
Recorder
Paper: 50mm thermal.
Speed: 12.5mm/sec 25mm/sec 50mm/sec. User-selectable 6-second delay.
Printing Method: High-resolution thermal print head.
Print-out Modes: Manual or automatic user-configurable.
On/Off Control: Front panel and paddle.
Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.
AED Mode
AED Function: Auto analyze and charge x3 with programmable auto energy level selection screen prompts and voice prompts.
Shockable Rhythms: Ventricular fibrillation with amplitude >=200uV ventricular tachycardia with rates >=140bpm and QRS complex wave duration >=140ms.
Charge Control: Control on device front panel press key on paddle.
Prompts: Voice and visual prompts.
Manual Mode
Energy Selection: Selectable at 2 5 7 10 20 30 50 70 100 150 200 300 360 joules.
Synchronized Mode: Synchronizes defibrillator pulse to patients
R-wave. SYNC message displayed on monitor.
SpO2 Module (Options):
The Specification of physical electronic isolation defibrillator battery electromagnetic compatibility and rhythm recognition performance will be described in this section:
Data Acquisition and Analysis
The Defi Xpress is no longer automatically configured to a certain frequency response. There are two diagnostic frequency options: 0.05-150 Hz
Diagnostic Frequency Filter and 0.05-40 Hz Filtered Diagnostic
Freq
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.