Description
Higer yields.
Improve self-consumption ratio up to 80%, reducing your electricity bill.
DC/AC ratio up to 1.3, completely suitable for double-side PV modular.
Two MPPT design, Max. efficiency of 97.6%.
User-friendly.
LCD Touch screen and buttons, easy operation.
Compatible with lithium-ion battery and lead acid battery.
Web browser and mobile App monitoring supported.
Reliable.
PV lighting protection, Anti-islanding protection, Leakage current protection etc.
Support store energy from DG when needed, ensure the system working within 7*24H.
IP65 protection degree, adapt to indoor and outdoor using.
Automatically switch from on-grid to off-grid mode within 5ms.
Zero exporting function, fast reaction within 200ms in zero export mode.
Smart.
Programmable charging and discharging schedule.
Both wind turbines and solar panels can be connected as DC input power.
Max. 16 units can be paralleled for higher system power.
Retrofitting of existing solar system to energy storage system.
Battery Input Data
Battery Type: Lead-acid or Li-lon
Battery Voltage Range (V): 40-60V
Max. Charging Current (A): 190A
Max. Discharging Current (A): 190A
Charging curve: 3 Stages/Equalization
External Temperature Sensor: Optional
Charging Strategy for Lithium Battery: Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W): 15400W.
PV input Voltage (V): 370V (100V-500V).
MPPT Range (V): 125-425V.
Start-up Voltage (V): 150V.
PV Input Current (A): 22A + 22A.
No. of MPPT Trackers: 2
No. of Strings Per MPPT Tracker: 2+2.
AC Output Data
Rated Power: 16,000 W
Min PPT Voltage: 150 V
Max PPT Voltage: 450 VDC
Startup Voltage: 150 VDC
Shutdown Voltage: 150 V
Max Input Voltage: 450 V
Max DC Power: 18,000 W
Max AC Power: 16,000 W
Surge AC Power: 24,000 W
Max DC Current: 66 A
Max DC Inputs: 6
Euro Efficiency: 97 %
MPPT Quantity 3
Efficiency
Max. Efficiency: 97.60%
Euro Efficiency: 97.00%
MPPT Efficiency: 99.90%
Protection
PV Arc Fault Detection: Integrated (Except European Type)
PV Input Lightning Protection: Integrated
Anti -islanding Protection: Integrated
PV String Input Reverse Polarity Protection: Integrated
Insulation Resistor Detection: Integrated
Residual Current Monitoring Unit: Integrated
Output over Current Protection: Integrated
Output Shorted Protection: Integrated
Output over Voltage Protection: Integrated
Certifications and Standards
Grid Regulation: UL1741, IEEE1547, RULE21, VDE0126, AS4777, NRS2017, G98, G99, IEC61683, IEC62116, IE61727
Safety Regulation: IEC62109-1, IEC62109-2
EMC: EN61000-6-1, EN61000-6-3, FCC 15 class B
General Data
Operating Temperature Range ( C ): -2560 C , >45 C Derating
Cooling: Fan
Noise (dB):