Description
LinkQnet True Online Pure Sinewave Tower Series UPS (1kVA ~ 3kVA)The LinkQnet 1 ~ 3kVA Online UPS Series are Reliable (Online Double Conversion, PF:0.99) and Compact in Size.Thanks to the New Battery Discharge Protection Control Function, It is Perfect for Medium Voltage Substation Applications.FEATURES:
Online double conversion
High power density
Online double conversion with full digital control
Wide input voltage range:110~300Vac
Input power factor 0.99 with PFC
Selectable output voltage: 208/220/230/240Vac
Smart charger design for optimized battery performance
Maximum charging current can be expanded to 12A (Long run unit)
Emergency power off function (EPO)
ECO mode operation for energy saving
Generator compatible
Cold start
Intelligent fan speed regulation
Versatile LCD human-computer interface
Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
Multiple protection function:short-circuit,overload,overheat, battery overcharge and overdischarge, output low voltage and fan fault alarm
SPECIFICATIONS:
Capacity:
1000VA/900W
3000VA/2700W
INPUT:
Nominal Voltage:
208/220/230/240Vac
Input Voltage Range:
110~300Vac (176~280Vac @ 100% load)
Frequency Range:
40~70Hz (50/60Hz Auto-Sensing)
Power Factor:
0.99
OUTPUT:
Output Voltage:
208/220/230/240Vac
Power Factor:
0.9
Voltage Regulation:
1%
Output Frequency:
Line Mode:
46~54Hz or 56~64Hz
Bat. Mode:
(50/600.1%)Hz
Crest Factor:
03:01
Harmonic Distortion (THDv):
3% Linear load
5% Non linear load
Transfer Time:
AC mode to Bat Mode:
0ms
Inverter to Bypass:
4ms (Typical)
Output Waveform:
Pure Sinewave
EFFICIENCY:
AC Mode:
88%
91%
Battery Mode:
85%
88%
BATTERY:
Battery Number:
2
6
Capacity (Standard Unit):
Standard Run models have internal 9Ah/12V VRLA Batteries Installed. Extended Run models cannot accept internal batteries and require an external battery solution.
Typical Recharging Time:
4 hours (to 90% of full capacity)
Charging Voltage:
27.4Vdc1%
82.2Vdc1%
Charging Current (Max.):
1A
INDICATORS:
LED Display:
Line mode, Bat.mode, ECO mode, Bypass mode, Battery low voltage, Overload & UPS fault
LCD Display:
Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Alarm:
Battery Mode:
Beeping every 4 seconds
Battery Low:
Beeping every second
Overload:
Beeping twice every second
Fault:
Continuously beeping
Physical:
Dimensions W * D * H (mm):
144 * 293 * 209
191 * 460 * 337
Net Weight (kg):
9.3
24.5
Environment:
Operating Temperature:
0C~40C
Storage Temperature:
-25C~55C
Humidity Range:
20~95%RH @ 0~40C (Non condensing)
Altitude:
1500m
Noise Level: